Manual TCP/IP Configuration

If the DHCP server is not available, or the BlueBox is not discoverable due to not being located in the same broadcast domain, you have to assign the IP address manually.

 

In the TCP/IP Configuration window, the IP Address, the Subnet Mask and the TCP Port must be specified. The default gateway address must be specified, if the debugger is used via a gateway. The IP Address, the Subnet Mask and the default gateway are usually defined by your network administrator. The TCP Port can be any port between 1024 and 65535, which is not already used on your LAN. By default, the TCP port 5313 is used. For the information, if this port address could cause any conflicts and for an alternative port address, also contact your network administrator. Debugger’s MAC address is written on the same sticker where you will also find device serial number.

 

i-icon

If the BlueBox is configured to acquire the IP address from a DHCP server, but this fails, it will use the IP configuration specified in IP Address/Subnet Mask fields.

 

 

Set a fixed IP address

number1

Open Hardware / Debugger Hardware / Hardware Type / System Configuration.

CommunicationConfigurationIPmanual

 

number2

Uncheck Obtain IP address automatically (DHCP).

number3

Enter your chosen fixed IP address manually.

Number4

Press Apply changes button.

This writes the changes to the BlueBox.

 

Number5

Power-cycle the BlueBox.

 