Please enable JavaScript to view this site.

Samtec22 to HSTCU (USB-C) Converter

Click to expand

 

 

Ordering code

IASAM22-HSTCU

This converter is used to connect Infineon AGBT Active Probe to the TriBoards with HSTCU (High Speed Tool Connector USB-C).  It must be ordered separately.

 

i-icon

When attaching this converter to the Active Probe, make sure its marking A and marking B is aligned and matches with the markings on the Active Probe connector.

 

The following pinout is valid on the target side:

Signal Direction

Signal Description

Signal

Pin

Pin

Signal

Signal  Description

Signal Direction

 

Ground

GND

A1

B12

NC

Not Connected

 

I

AGBT TX0_P

TX0+

A2

B11

CLK+

AGBT Clock

O

I

AGBT TX0_N

TX0-

A3

B10

CLK-

AGBT Clock

O

 

Not Connected

NC

A4

B9

NC

Not Connected

 

I/O

Target Reset Pin

nRESET

A5

B8

DAP1

DAP Data

I

I/O

Optional 2nd DAP data

DAP2

A6

B7

nTRST

Output

O

I/O

Optional 3rd DAP data

DAP3

A7

B6

NC

Not Connected

 

O

DAP Clock

DAP0

A8

B5

Vref

Reference Voltage

I

 

Not Connected

NC

A9

B4

NC

Not Connected

 

 

Not Connected

NC

A10

B3

NC

Not Connected

 

 

Not Connected

NC

A11

B2

NC

Not Connected

 

 

Ground

GND

A12

B1

GND

Ground

 

(HSTCU) USB-C pinout

 

Blue colored signals are trace signals.

 

Signal Direction is described from the BlueBox perspective.

 

Warning_orange

When initially connecting the BlueBox to a target, ensure the debug adapter pinout matches the Target connector to avoid potential hardware failure.

 

Copyright © 2025 TASKING