Device description
|
A – 40-pin HSSTP connector with 20cm high-speed cable and the following pinout:
Signal Direction |
Signal Description |
Signal |
Pin |
Pin |
Signal |
Signal Description |
Signal Direction |
---|---|---|---|---|---|---|---|
O |
HSSTP Lane 4 |
Tx4_P |
1 |
2 |
Vref |
Reference Voltage |
I |
O |
HSSTP Lane 4 |
Tx4_N |
3 |
4 |
TCK/SWCLK |
JTAG / SWD |
O |
|
Ground |
GND |
5 |
6 |
GND |
Ground |
|
O |
HSSTP Lane 2 |
Tx2_P |
7 |
8 |
TMS/SWDIO |
JTAG / SWD |
I/O |
O |
HSSTP Lane 2 |
Tx2_N |
9 |
10 |
nTRST |
JTAG |
O |
|
Ground |
GND |
11 |
12 |
GND |
Ground |
|
O |
HSSTP Lane 0 |
Tx0_P |
13 |
14 |
TDI |
JTAG |
O |
O |
HSSTP Lane 0 |
Tx0_N |
15 |
16 |
TDO |
JTAG |
I |
|
Ground |
GND |
17 |
18 |
GND |
Ground |
|
O |
HSSTP Clock |
CLK_P |
19 |
20 |
nRESET |
RESET |
O |
O |
HSSTP Clock |
CLK_N |
21 |
22 |
DBGREQ |
Debug Request |
O |
|
Ground |
GND |
23 |
24 |
GND |
Ground |
|
O |
HSSTP Lane 1 |
Tx1_P |
25 |
26 |
DBGACK |
Debug Acknowledge |
I |
O |
HSSTP Lane 1 |
Tx1_N |
27 |
28 |
RTCK |
Return TCK |
I |
|
Ground |
GND |
29 |
30 |
GND |
Ground |
|
O |
HSSTP Lane 3 |
Tx3_P |
31 |
32 |
TRIGIN |
CTI Trigger Input |
I |
O |
HSSTP Lane 3 |
Tx3_N |
33 |
34 |
TRIGOUT |
CTI Trigger Output |
O |
|
Ground |
GND |
35 |
36 |
GND |
Ground |
|
O |
HSSTP Lane 5 |
Tx5_P |
37 |
38 |
GND |
Ground |
|
O |
HSSTP Lane 5 |
Tx5_N |
39 |
40 |
GND |
Ground |
|
40-pin HSSTP pinout
Blue colored signals are trace signals.
Signal direction definition:
O - Output from the Active Probe to the target microcontroller
I - Input to the Active Probe from the target microcontroller
The target microcontroller connector is a Samtec ERF8 series, rugged high-speed socket, part number ASP-130367-01.
B – mDIO port marked as TRIG on the housing
mDIO port provides two digital signals, which can interact with the embedded target. Each can be configured either for input or output operation.
C – The indicator light provides the status of the Active Probe as follows:
Permanently green – Powered on and ready to use. |
|
Blinking green – Establishing connection with the BlueBox. |
|
Blinking blue – Reprogramming SPLASH. |
|
Permanently magenta – Golden image loaded and ready to use. |
D – FNet connector, that connects the Active Probe to the iC7max or iC5700. The FNet cable is delivered with the Active Probe.
When powering on the system, switch the BlueBox on before powering on the target. When powering down the system, power off the target before powering off the BlueBox! Use only original accessories for powering and connecting with the BlueBox. Consult with technical support before attempting to use any other accessory. |