Please enable JavaScript to view this site.

Hardware Setup and Configuration

i-icon

For detailed visual presentation of the hardware setup and configuration, refer to the Getting started tutorial.

 

 

1. Connect the power supply cable. BlueBox should be switched off.

 

2. First connect the BlueBox to the PC via USB cable. Later you can configure TCP/IP connection to work remotely.

 

3. Connect the Grounding wire to the BlueBox and the Target.

 

Warning_orange

If the Grounding wire is not connected, the ground potential difference between the BlueBox and the Target can exceed well over 1000V even before any of the devices are powered up. This voltage difference is discharged over the BlueBox and the Target, leading to the possible destruction of electronic components.

 

4. Connect FNet cable of Active Probe to the iC7max/iC5700 BlueBlux FNet port.

 

5. Connect Active Probe's ribbon cable(s) to the Target.

 

Warning_orange

Although it looks similar to the HDMI interface, the FNet Port is not compatible with HDMI or any HDMI accessories.

Connecting the hardware to HDMI accessories will damage the hardware and will render the hardware warranty void.

 

6. Power ON the hardware in the following order:

a.BlueBox

b.Target

 

7. Install winIDEA and create a new workspace.

 

8. Configure Debug channel modes via Hardware / CPU Options / SoC.

 

 

i-icon

For troubleshooting refer to Knowledge Base.

 

hmtoggle_arrow0 More general settings are described in winIDEA Help.