Please enable JavaScript to view this site.

Device description

 

usbc-top

 

usbc-back

 

A – USB-C connector, with the following pinout:

Signal Direction

Signal Description

Signal

Pin

Pin

Signal

Signal  Description

Signal Direction

 

Ground

GND

A1

B12

NC

Not Connected

 

I

AGBT TX0_P

TX0+

A2

B11

CLK+

AGBT Clock

O

I

AGBT TX0_N

TX0-

A3

B10

CLK-

AGBT Clock

O

 

Not Connected

NC

A4

B9

NC

Not Connected

 

I/O

Target Reset Pin

nRESET

A5

B8

DAP1

DAP Data

I

I/O

Optional 2nd DAP data

DAP2

A6

B7

nTRST

Output

O

I/O

Optional 3rd DAP data

DAP3

A7

B6

NC

Not Connected

 

O

DAP Clock

DAP0

A8

B5

Vref

Reference Voltage

I

 

Not Connected

NC

A9

B4

NC

Not Connected

 

 

Not Connected

NC

A10

B3

NC

Not Connected

 

 

Not Connected

NC

A11

B2

NC

Not Connected

 

 

Ground

GND

A12

B1

GND

Ground

 

(HSTCU) USB-C pinout

 

Blue colored signals are trace signals.

 

Signal direction definition:

O – Output from the Active Probe to the target microcontroller

I  – Input to the Active Probe from the target microcontroller

 

B – mDIO port marked as TRIG on the housing

 

mDIO port provides two digital signals, which can interact with the embedded target. Each can be configured either for input or output operation.

 

Number

Name

Pin1

IOØ

Pin2

IO1

Pin3

GND

mDIO port pinout

mdioport-pindesignation_zoom16

mDIO port on the Active Probe

 

C – The indicator light provides the status of the Active Probe as follows:

 

permanently-green

Permanently green – Powered on and ready to use.

blinking-green

Blinking green – Establishing connection with the BlueBox.

blinking-blue

Blinking blue – Reprogramming SPLASH.

permanently-magenta

Permanently magenta – Golden image loaded and ready to use.

 

D – FNet connector, that connects the Active Probe to the iC7max or iC5700. The FNet cable is delivered with the Active Probe.

 

Warning_orange

When powering on the system, switch the BlueBox on before powering on the target. When powering down the system, power off the target before powering off the BlueBox!

Use only original accessories for powering and connecting with the BlueBox. Consult with technical support before attempting to use any other accessory.

Copyright © 2024 TASKING Germany GmbH