This tutorial introduces the Operating System (OS) objects profiling configuration via Automatic Hardware Trigger Configuration.

It shows how to configure your OS, add an RTOS description file which is a necessary step for profiling OS objects.

 

 

Configuration steps

Make sure your winIDEA workspace for tracing is created and debug session established.

 

number1

Go to Debug | Configure Session | Application | Edit and select your operating system.

Profiling-os-objects-orti-xml

 

 

number2

Click the Configure button and specify the RTOS description file.

rtos-orti-file-specify

 

 

number3

Create a New Analyzer Configuration via View | Analyzer | Analyzer Configuration arrow | Create New Configuration.

The configuration should have:

a.Descriptive name

b.Enabled Profiler

c.Enabled Automatic Hardware Trigger

 

Profiling-os-objects-new-config

 

 

Number4

Add a Process via New button.

Profiling-data-tutorial-process

 

When you click on the newly created Process (e.g. App/MS_App), Profiler (and Coverage) pages will appear in the left menu.

 

Number5

Set Recorder options.

Start - Trigger Immediately

(optional) Enabled Upload while sampling to stream trace messages via the DAP interface

 

profiling-data-recorder-winidea

 

Warning_orange

Make sure Manual Hardware Trigger is not checked.

 

 

number6

Enable OS object section and select OS object and values.

profiling-os-objects-runnables

 

 

 

 

Results

profilling-os-objects-results_zoom52

 

 

More resources

Recorder - Configuration details

OS Profiling - Configuration details

 

 